Laboratory · Electrical Engineering
The DC Machine and Transformer Laboratory is a practical learning facility of the Electrical Engineering Department designed to develop students’ understanding of electrical machines through hands-on experimentation and performance analysis.
Key features of the laboratory:
Provides practical exposure to DC generators, DC motors, and single/three-phase transformers.
Enables students to study construction, operating principles, characteristics, testing, and applications.
Supports experiments such as OCC, load test, brake test, Swinburne’s test, open-circuit and short-circuit tests, efficiency, and voltage regulation.
Provides experience in using voltage, current, power, speed, and other electrical measuring instruments.
Develops skills in data collection, calculation, graphical analysis, and interpretation of experimental results.
Emphasizes electrical safety, proper machine operation, and laboratory practices.
Helps students correlate theoretical concepts with practical machine performance.
Supports project-based learning, troubleshooting, and problem-solving skills.
Strengthens competencies required for industrial applications, maintenance, testing, and commissioning.
Contributes to Outcome-Based Education (OBE) by developing practical skills and measurable laboratory learning outcomes.
Major Equipment Required for DC Machine & Transformer Laboratory
S. No. | Experiment | Major Equipment Required |
|---|---|---|
1 | Speed control of DC shunt motor – field and armature control | DC shunt motor, DC motor–generator set, DC power supply, field rheostat, armature rheostat, tachometer/digital RPM meter, voltmeter, ammeter, connecting leads |
2 | DC series motor characteristics | DC series motor, DC power supply, loading arrangement/brake, rheostat, ammeter, voltmeter, tachometer, wattmeter |
3 | OCC of DC shunt generator | DC shunt generator, DC shunt motor as prime mover, field rheostat, DC supply, voltmeter, ammeter, tachometer |
4 | Load characteristics of DC shunt generator | DC shunt generator, DC motor prime mover, electrical load bank, field rheostat, voltmeter, ammeter, wattmeter, tachometer |
5 | Load test on DC shunt motor and efficiency | DC shunt motor, DC supply, brake/loading arrangement, spring balance/load cell, voltmeter, ammeter, wattmeter, tachometer |
6 | Speed–torque characteristics of DC shunt motor | DC shunt motor, variable DC supply, loading arrangement, torque measurement system, tachometer, voltmeter, ammeter, wattmeter |
For the following experiments, the laboratory can use virtual-lab simulations where physical equipment is not available:
S. No. | Experiment | Major Equipment / Virtual Facility |
|---|---|---|
7 | Construction and working principle of single-phase transformer | Single-phase transformer demonstration unit / Virtual Transformer Lab |
8 | Open-circuit test on single-phase transformer | Single-phase transformer, variac, AC voltmeter, ammeter, wattmeter / Virtual Lab simulation |
9 | Short-circuit test on single-phase transformer | Single-phase transformer, variac, AC voltmeter, ammeter, wattmeter / Virtual Lab simulation |
10 | Efficiency and voltage regulation of transformer | Single-phase transformer, variac, load bank, voltmeter, ammeter, wattmeter / Virtual Lab simulation |
11 | Load test on single-phase transformer | Single-phase transformer, variable AC supply/variac, resistive load bank, voltmeter, ammeter, wattmeter / Virtual Lab simulation |